STEP DESCRIPTION MESSAGE
DISPLAY
FUNCTION AVAILABLE SETTING
4d Deviation
(High/Low)
Alarm 1 value
DeAlarm 1 If Alarm 1 is a Deviation High/Low
alarm, gives a value above (positive
value) or below (negative value) the
setpoint. If the process variable
deviates from the setpoint by a
margin greater than this value, the
alarm becomes active
± (input range) from
setpoint. Default =
five input range units.
5 Alarm 1
Hysteresis
value
Al1 Hyst Value defines a hysteresis band on
the “safe” side of the alarm 1 value
1 unit to X units,
where X = 10% of
input span
6a Process High
Alarm 2 value
HiAlarm 2 If Alarm 2 is a Process High alarm,
the value of process variable at or
above which Alarm 2 will be active
Input Range Max. to
Input Range Min.
Default = Input Range
Max.
6b Process Low
Alarm 2 value
LoAlarm2 If Alarm 2 is Process Low Alarm, the
value of process variable at or below
which Alarm 2 will be active
Input Range
Max. to Input
Range Min.
Default =
Input Range Min.
6c Band Alarm 2
value
BaAlarm2 If Alarm 2 is a Band Alarm, the band
of process variable values (centered
on the setpoint) outside which the
process variable will cause this alarm
to be active.
± (input span) from
setpoint. Default =
five input units.
6d Deviation
(High/Low)
Alarm 2 value
DeAlarm 2 If Alarm 2 is a Deviation High/Low
Alarm, gives a value above (positive
value) or below (negative value) the
setpoint. If the process variable
deviates from the setpoint by a
margin greater than this value, the
alarm becomes active.
± (input range) from
setpoint. Default =
five input range units
7 Alarm2
Hysteresis
Value
Al2 Hyst A non-zero value defines a hysteresis
band on the “safe” side of the Alarm 2
value
1 unit to X units,
where X = 10% of
input span
8 Loop Alarm
Enable
Loop Alm Enables/disables Loop Alarm EnAb
disA
Default = disA
9 Loop Alarm
Time
LpAtime If ON/OFF control is selected (i.e.
PB1=0) and Loop Alarm is enabled,
this defines the duration of the
saturation condition after which the
Loop Alarm is activated.
1 second to 99
minutes 59 seconds.
Default = 99 minutes
59 seconds
Vedere la pagina 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 111 112

Commenti su questo manuale

Nessun commento

Snapper Zahradní nářadí uživatelské příručky

Začínající na S

Klepnutím na abecedu níže přejděte na úplný seznam modelů začínajících tímto písmenem

Modely Typ Dokumentu
SV25550HC
Uživatelský manuál   Snapper SV25550HC User's Manual, 16 stránky
SV25650B
Uživatelský manuál   Snapper SV25650B User's Manual, 16 stránky