Modbus Programming Manual ADDRESS LIST
Version 2 39
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
2.9.5.2. Editing/Creating a profile header at a location (Command Code EP
or WP)
Creating Or Editing A Profile Header at a specific location - Request (to instrument)
The ID address of the instrument.
Requires the multi read/write function.
Read Start Address High Byte
Read Start Address Low Byte
Read Quantity Of Registers High Byte
Read Quantity Of Registers Low Byte
Write Start Address High Byte
Write Start Address Low Byte
Write Quantity Of Registers High Byte
Write Quantity Of Registers Low Byte
42dec / 0x2Ahex if creating a profile at a
specified location, or editing a profile.
Edit Profile (EP) = 17744dec / 0x4550hex
Write Profile (WP) = 23352dec / 0x5750hex
The profile number can be anything between
0 and 64
The ASCII codes equivalent to each of the
16 characters of the profile name, e.g. :
A = 65dec / 0x41, B = 66dec / 0x42 etc
a = 97dec / 0x61, b = 98dec / 0x62 etc
Note: Only valid characters from the
instruments supported character set
should be used
The space character (32dec / 0x20hex) is
used to fill any unused characters at the end
of the name
Characters 9 to 16 are not supported and
should be written to 32dec / 0x20hex
.
Profile Name Character 10
Profile Name Character 11
Profile Name Character 12
Profile Name Character 13
Profile Name Character 14
Profile Name Character 15
Profile Name Character 16
Profile Start Signal High Byte
0 = No delay, 1 = After delay, 2 = At
Time/day
Profile Start Signal Low Byte
Profile Start Time (Byte 4 - High)
Profile Start Time (Byte 3)
Profile Start Time (Byte 2)
Profile Start Time (Byte 1 - Low)
Profile Start Day High Byte
1 = Monday, 2 = Tuesday, 3 = Wednesday,
4 = Thursday, 5 = Friday, 6 = Saturday,
7 = Sunday, 8 = Monday to Friday,
9 = Monday to Saturday,
10 = Saturday And Sunday, 11= All Week
Profile Start Day Low Byte
Profile Starting Setpoint High
1 = Current Process Variable Value
Commenti su questo manuale